CompuSTAR 2W803R-SS Manuale di Installazione

Navigare online o scaricare Manuale di Installazione per Alarme antifurto per auto CompuSTAR 2W803R-SS. CompuSTAR 2W803R-SS Installation manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 55
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Please visit techfeed.compustar.com for additional installation resources
Firstech, LLC.
21903 68th Ave S.
Kent, WA 98032
Phone. 888-820-3690
Fax. 206-957-3330
Master Guide
CM7200 Starter System
Version 2014 Rev 1
Vedere la pagina 0
1 2 3 4 5 6 ... 54 55

Sommario

Pagina 1 - Master Guide

Please visit techfeed.compustar.com for additional installation resourcesFirstech, LLC.21903 68th Ave S.Kent, WA 98032Phone. 888-820-3690Fax. 206-95

Pagina 2

Knock Panel SensitivityTo change knock sensitivity, disarm the system and adjust the switch on the rear of the RPS. The larger the circle, the more se

Pagina 3

Testing The DAS SensorSTEP 1: Turn the ignition off and Arm/Lock the system. STEP 2: Wait 30 seconds then test the impact sensitivity.FT-EZGO SetupThe

Pagina 4

Jumper SettingsCaution: Jumper settings affect the polarity and use of certain outputs. If these jumpers are used incorrectly, damage to the vehicle

Pagina 5

Jumper 2 (2nd Ignition / 2nd Starter / 2nd Parking light)Jumper 2 sets the behavior of the large blue wire on Connector 1. This wire is powered by an

Pagina 6

Copyright 2014 Firstech, LLC. Page 2Copyright 2014 Firstech, LLC. Page 2CM7200 Master GuideStarter Systemtechfeed.compustar.comCopyright 2014 Firstech

Pagina 7

Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 15CM7200 Master GuideStarter Systemtechfeed

Pagina 8

Copyright 2014 Firstech, LLC. Page 2Copyright 2014 Firstech, LLC. Page 2CM7200 Master GuideStarter Systemtechfeed.compustar.comCopyright 2014 Firstech

Pagina 9

Connector 1 (CN1), 8-PinPin 1 Red - Constant 12V positive (+) power input. This wire must be connected. The proper wire will test (+) 12V at all times

Pagina 10 - CM7200 Master Guide

Copyright 2014 Firstech, LLC. Page 2Copyright 2014 Firstech, LLC. Page 2CM7200 Master GuideStarter Systemtechfeed.compustar.comCopyright 2014 Firstech

Pagina 11

Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 19CM7200 Master GuideStarter Systemtechfeed

Pagina 12

Introduction 4Kit Contents 4Installation Basics 5Remote Programming Routine 6Valet Mode 6Placement

Pagina 13

Copyright 2014 Firstech, LLC. Page 2Copyright 2014 Firstech, LLC. Page 2CM7200 Master GuideStarter Systemtechfeed.compustar.comCopyright 2014 Firstech

Pagina 14

Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 21CM7200 Master GuideStarter Systemtechfeed

Pagina 15

Pin 18 Yellow/Black - Engine sensing input (A/C): This wire is connected to the vehicle’s Tach or Alternator wire and is required when using the tach

Pagina 16

Pin 2 Black/White – thermister: temp resistance input. Connector 9 (CN9), 4-Pin to 4-Pin or 6-Pin (Pre-wired Antenna Cable)Connect your antenna cable

Pagina 17

Pin 3 Orange/Black - 2nd Unlock 250mA negative (-) output: This is an optional output that will provide a (-) pulse for driver’s priority door lock. I

Pagina 18

Option Programming TablesCopyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 25CM7200 Master Gu

Pagina 19

Copyright 2014 Firstech, LLC. Page 2Copyright 2014 Firstech, LLC. Page 2CM7200 Master GuideStarter Systemtechfeed.compustar.comCopyright 2014 Firstech

Pagina 20

Special Option Group 1Feature Setting Value (Seconds)1 Diesel Timer - DISL 3 ~ 992 AUX1 output time 1 ~ 1003 AUX2 output time 1 ~ 1004 AUX3 output tim

Pagina 21

Copyright 2014 Firstech, LLC. Page 2Copyright 2014 Firstech, LLC. Page 2CM7200 Master GuideStarter Systemtechfeed.compustar.comCopyright 2014 Firstech

Pagina 22

Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 29CM7200 Master GuideStarter Systemtechfeed

Pagina 23

Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 3CM7200 Master GuideStarter Systemtechfeed.

Pagina 24

1-06 Reservation Lock: Optional manual transmission reservation mode procedures.FO1 - Locks before set: (default) this option will lock the doors bef

Pagina 25

1-09 Ignition Controlled Locks: When FO 2-4 are selected, the user can activate the “drive lock” or ignition controlled door locking feature using a F

Pagina 26

1-13 Double pulse disarm: This feature enables the FAD output. It will pulse 2 times with a single disarm command.FO1 - Off (default): Standard singl

Pagina 27

2-01 Tach Sensing Method: This feature will determine the point at which the CM7 releases the starter based on the sampled tach method.FO1 - Optimal T

Pagina 28

2-04 Trigger Start: This feature changes the number of pulsed inputs (min of 60mS per pulse) on the trigger start input wire. (Pink wire CN5). Note: I

Pagina 29

FO3 - Reserve runtime: (runtime based on feature 2-07 option setting) Note: 2 way LCD remote required. This option will allow the user to set a predet

Pagina 30

2-10 Engine Sensing: This feature provides 4 options for engine sensing methods. Every CM7 is shipped in manual transmission mode. Tach sensing is our

Pagina 31

2-14 PIC 1 (-): Programmable Input Channel provides 4 options for negative input to the CM7.FO1 - (-) negative E-brake (aka: parking brake) input: Thi

Pagina 32

3-03 Dome Light Delay: This option is used when connecting the door trigger input to the vehicles dome light circuit. It delays the door trigger input

Pagina 33

FO4 - On double lock and Start: this option is design to simulate a factory keyless entry system by providing a horn output pulse (based on the option

Pagina 34

All Firstech FT-7200S CONT controllers include the following:• CM7200 main control module• Wiring diagram sheet• High Current ignition harness with

Pagina 35

3-12 VAC: (Thermister required) this determines the temperature at which the CM7 will provide an output on any POC programmed with setting 22(VAC: Ven

Pagina 36

3-15 Soft Disarm: this feature will enable Factory Alarm Arm (FAA) and Factory Alarm Disarm (FAD) outputs to trigger when silencing the Compustar sire

Pagina 37

4-02 Aux 2 Output: This feature determines the duration of the auxiliary 2 output. (Option 4 allows the output duration to be set for a specific le

Pagina 38

FO3 - With Disarm: this option will trigger AUX 2 (output time based on feature 4-02) any time the CM7 is unlocked/disarmed. Note: the system has to b

Pagina 39

4-10 PIC 4 (+): (Programmable input Channel 4 CN5 pin 14 Pink) this feature will determine the input function of PIC4.FO1 - Trigger start input: This

Pagina 40

FO3 - 48hrs (2 days): This option will allow the antenna to power down 48hrs after being armed. Note: once the antenna has powered down, 1 Way operati

Pagina 41

This special option group allows you to determine the output type of the POC wire. For example, if you want to set POC #5 (default setting status out)

Pagina 42

SV 10 - AUX1: provides a 250mA (-) negative output when AUX is triggered by Firstech 4 button remote, 2way LCD remote, or Drone, on any POC programmed

Pagina 43

How to Program OptionsThere are two ways to set options on the CM7 control modules. You can use the FT-OP500-KIT or most Firstech remotes. The remotes

Pagina 44

Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 49CM7200 Master GuideStarter Systemtechfeed

Pagina 45

Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 5CM7200 Master GuideStarter Systemtechfeed.

Pagina 46

Copyright 2014 Firstech, LLC. Page 2Copyright 2014 Firstech, LLC. Page 2CM7200 Master GuideStarter Systemtechfeed.compustar.comCopyright 2014 Firstech

Pagina 47

Remote Start Error CodesIf the remote start fails to start the vehicle, the parking lights will flash three times immediately. Following those two fla

Pagina 48

Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 52CM7200 Master GuideStarter Systemtechfeed

Pagina 49

I need a ground when armed wire, does the control module have one?A: You can use pin 1-blue/white wire on the Grey Connector 5. You must cut this wire

Pagina 50

What is this cartridge slot on the CM7000, CM7200, and CM6300?A: This is the slot for the Blade cartridge system. This slot is for the Idatalink Blade

Pagina 51

Copyright 2014 Firstech, LLC. Page 2Copyright 2014 Firstech, LLC. Page 2CM7200 Master GuideStarter Systemtechfeed.compustar.comCopyright 2014 Firstech

Pagina 52

Copyright 2014 Firstech, LLC. Page 2Copyright 2014 Firstech, LLC. Page 2CM7200 Master GuideStarter Systemtechfeed.compustar.comCopyright 2014 Firstech

Pagina 53

Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 7CM7200 Master GuideStarter Systemtechfeed.

Pagina 54

Copyright 2014 Firstech, LLC. Page 2Copyright 2014 Firstech, LLC. Page 2CM7200 Master GuideStarter Systemtechfeed.compustar.comCopyright 2014 Firstech

Pagina 55

Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 9CM7200 Master GuideStarter Systemtechfeed.

Commenti su questo manuale

Nessun commento